House Connection Testing System - Complete Set by Aquametrics with Measuring Device RPS03
Aquametrics House Connection Testing System – Complete Set with Measuring Device (RPS03)
Complete solution for leak testing of house connections using air. Optionally also suitable for water testing.
- DIN EN 1610
- DIN EN 1986-30
- DWA A-139
Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.
Advantages
- Practically developed in-house – “By inspectors – for inspectors”
- Easy transport in a durable plastic case
- Test bladder with aluminum core – lightweight and user-friendly
- Short design length – ideal for narrow manholes and inspection openings
- Test bladder can be used independently without push hose
- Precise positioning via push hose with locking compression fitting
- Flexible push and sealing bladders for use in pipe bends
Standard-Compliant Testing
Our leak tests are performed in accordance with the following standards:
- DIN EN 1610
- DWA-A 139
- DIN 1986-30
- DWA-M 149-6 (formerly ATV-M 143-6)
- DIN 1999-100
- DIN 4040-100
- DIN EN 805
- DVGW-W400
Versatile Applications
Our measuring systems are also commonly referred to as:
- Test case, pressure test case, pressure measurement case, sealing case
- Water level probe, manhole probe
- Water level test, septic tank test, small treatment plant test, container test, collection tank test, water pressure test
- House connection test, house connection tester, house connection testing unit
- Vacuum test, negative pressure test, vacuum ejector
- Leak testing of private wastewater pipes and sewer systems
Scope of Delivery
- Aquametrics house connection testing system with sealing bladder
- Handheld measuring device (RPS03 system)
- Push rod 12 m (blue)
- Durable plastic case
- AquaDP software (module "Luft") on USB flash drive - in German
- Test documentation with data logging, time curve, and export as PDF
- Option to insert images into the test report
- Optional: Water testing module available
Maintenance and Service
Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection).
Recommended recalibration interval: 1 year.
Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
| Property | Value |
|---|---|
| Operating Pressure | 2.5 bar |
| Aluminum Core | DN 90–150 |
| Application Range | 90–150 mm |
| Diameter (unpressurized) | approx. 83 mm |
| Installation Length | 200 mm |
| Total Length | approx. 450 mm |
| Back Pressure | max. 0.5 bar |