House Connection Testing System with Air (without RPS03 Measuring Device)
House Connection Testing System with Air (without RPS03 measuring device)
Aquametrics testing system for leak detection in house connections. Optionally also suitable for water testing.
- DIN EN 1610
- DIN EN 1986-30
- DWA A-139
Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.
Advantages
- Practical in-house development – “By inspectors – for inspectors”
- Test bladder with aluminum core – lightweight and easy to handle
- Very short design – ideal for tight manholes and inspection openings
- Test bladder can be used independently without push hose
- Precise positioning via push hose with locking (compression fitting)
- Excellent flexibility of push and sealing bladders in bends
Our tests are conducted in accordance with the following standards:
- DIN EN 1610
- DWA-A 139
- DIN 1986-30
- DWA-M 149-6 (formerly ATV-M 143-6)
- DIN 1999-100
- DIN 4040-100
- DIN EN 805
- DVGW-W400
Scope of Delivery
- Aquametrics house connection testing system with sealing bladder
- Push bladder as conical pipe sealing cushion
- 12.5 m push hose
- Y-distributor for compressed air NW7.2
Maintenance and Service
Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection).
Recommended recalibration interval: 1 year.
Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
| Property | Value |
|---|---|
| Operating Pressure | 2.5 bar |
| Aluminum Core | DN 90–150 |
| Application Range | 90–150 mm |
| Diameter (unpressurized) | approx. 83 mm |
| Rubber Body | 200 mm |
| Total Length | approx. 450 mm |
| Back Pressure | max. 0.5 bar |