Skip to main content Skip to search Skip to main navigation
Go to homepage

House Connection Testing System with Air (without RPS03 Measuring Device)

Product information "House Connection Testing System with Air (without RPS03 Measuring Device)"

House Connection Testing System with Air (without RPS03 measuring device)

Aquametrics testing system for leak detection in house connections. Optionally also suitable for water testing.

  • DIN EN 1610
  • DIN EN 1986-30
  • DWA A-139

Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.

Advantages

  • Practical in-house development – “By inspectors – for inspectors”
  • Test bladder with aluminum core – lightweight and easy to handle
  • Very short design – ideal for tight manholes and inspection openings
  • Test bladder can be used independently without push hose
  • Precise positioning via push hose with locking (compression fitting)
  • Excellent flexibility of push and sealing bladders in bends

Our tests are conducted in accordance with the following standards:

  • DIN EN 1610
  • DWA-A 139
  • DIN 1986-30
  • DWA-M 149-6 (formerly ATV-M 143-6)
  • DIN 1999-100
  • DIN 4040-100
  • DIN EN 805
  • DVGW-W400

Scope of Delivery

  • Aquametrics house connection testing system with sealing bladder
  • Push bladder as conical pipe sealing cushion
  • 12.5 m push hose
  • Y-distributor for compressed air NW7.2

Maintenance and Service

Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). 

Recommended recalibration interval: 1 year.

Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.

Property Value
Operating Pressure 2.5 bar
Aluminum Core DN 90–150
Application Range 90–150 mm
Diameter (unpressurized) approx. 83 mm
Rubber Body 200 mm
Total Length approx. 450 mm
Back Pressure max. 0.5 bar
Skip product gallery

Zu diesem Produkt empfehlen wir Ihnen:

Measuring Device (RPS03 Solo) for Leak Testing of Pipelines and Manholes Using Air

Leak Testing System with Air For positive pressure and negative pressure testing of pipelines up to 200 mbar. DIN EN 1610 DIN 1986-30 DWA A-139 Suitable as an extension or supplement to existing test bladders. The required measurement accuracy according to DIN EN 1610 has been verified by expert report. Note: No data logger function! Recording is done directly via the AquaDP software. The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you. Advantages For measuring overpressure, underpressure and differential pressure Six differential pressure ranges from precision manometer Barometric pressure sensor and temperature compensation for highly accurate readings Large TFT color display (W × H: 45 × 60?mm) Measurement display in 9 different units: mbar, Pa, hPa, kPa, mmWS, mmHg, inWC, psi, bar Fully automatic device check, manual and automatic zero-point adjustment on program start Our tests are conducted according to the standards: DIN EN 1610, DWA-A 139, DIN 1986-30, DWA-M 149-6.Scope of Delivery Measuring device with power supply and data cable Calibration certificate Protective device cover with magnet Software (in German) on USB memory stick Bluetooth dongle for data transfer Aluminum transport case Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.