Skip to main content Skip to search Skip to main navigation
Go to homepage

Measuring Device (RPS03 Solo) for Leak Testing of Pipelines and Manholes Using Air

Product information "Measuring Device (RPS03 Solo) for Leak Testing of Pipelines and Manholes Using Air"

Leak Testing System with Air

For positive pressure and negative pressure testing of pipelines up to 200 mbar.

  • DIN EN 1610
  • DIN 1986-30
  • DWA A-139

Suitable as an extension or supplement to existing test bladders.

The required measurement accuracy according to DIN EN 1610 has been verified by expert report.

Note: No data logger function! Recording is done directly via the AquaDP software. The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.

Advantages

  • For measuring overpressure, underpressure and differential pressure
  • Six differential pressure ranges from precision manometer
  • Barometric pressure sensor and temperature compensation for highly accurate readings
  • Large TFT color display (W × H: 45 × 60?mm)
  • Measurement display in 9 different units: mbar, Pa, hPa, kPa, mmWS, mmHg, inWC, psi, bar
  • Fully automatic device check, manual and automatic zero-point adjustment on program start

Our tests are conducted according to the standards: DIN EN 1610, DWA-A 139, DIN 1986-30, DWA-M 149-6.

Scope of Delivery

  • Measuring device with power supply and data cable
  • Calibration certificate
  • Protective device cover with magnet
  • Software (in German) on USB memory stick
  • Bluetooth dongle for data transfer
  • Aluminum transport case

Maintenance and Service

Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). 

Recommended recalibration interval: 1 year.

Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.

Property Value
Temperature Range Ambient: 0–40 °C / Storage: -20 to +50 °C
Operating Time max. 38 hours
Display TFT color display, 2.8" / W x H: 45 x 60 mm
Interfaces Infrared, Bluetooth® Smart, QR code generator, MicroSD card slot
Power Supply Lithium-ion battery (3.6 V / 1,800 mAh) or power adapter (Mini-USB)
Weight approx. 250 g
Dimensions W x H x D: 66 x 143 x 37 mm
Skip product gallery

Zu diesem Produkt empfehlen wir Ihnen:

House Connection Testing System - Complete Set by Aquametrics with Measuring Device RPS03

Aquametrics House Connection Testing System – Complete Set with Measuring Device (RPS03) Complete solution for leak testing of house connections using air. Optionally also suitable for water testing. DIN EN 1610 DIN EN 1986-30 DWA A-139 Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Advantages Practically developed in-house – “By inspectors – for inspectors” Easy transport in a durable plastic case Test bladder with aluminum core – lightweight and user-friendly Short design length – ideal for narrow manholes and inspection openings Test bladder can be used independently without push hose Precise positioning via push hose with locking compression fitting Flexible push and sealing bladders for use in pipe bends Standard-Compliant Testing Our leak tests are performed in accordance with the following standards: DIN EN 1610 DWA-A 139 DIN 1986-30 DWA-M 149-6 (formerly ATV-M 143-6) DIN 1999-100 DIN 4040-100 DIN EN 805 DVGW-W400 Versatile Applications Our measuring systems are also commonly referred to as: Test case, pressure test case, pressure measurement case, sealing case Water level probe, manhole probe Water level test, septic tank test, small treatment plant test, container test, collection tank test, water pressure test House connection test, house connection tester, house connection testing unit Vacuum test, negative pressure test, vacuum ejector Leak testing of private wastewater pipes and sewer systems Scope of Delivery Aquametrics house connection testing system with sealing bladder Handheld measuring device (RPS03 system)Push rod 12 m (blue) Durable plastic case AquaDP software (module "Luft") on USB flash drive - in German Test documentation with data logging, time curve, and export as PDF Option to insert images into the test report Optional: Water testing module available Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.