Leak & House Connection Testing Equipment
- Pipe Plugs and Drain Test Plugs
- Mechanical Pipe Plugs & Shut-Off-Discs
- Sealing Bags and Lifting Bags
- Leak & House Connection Testing Equipment
- Mechanical Pipe Cleaning Products
- Partial Renovation with Short Liners
- Inliner Pipe Rehabilitation
- Sewer Cameras & Measuring Technology
- Compressors & Waste Water Pumps
- Manhole Safety
- Sewer Technology Tools & Accessories
- Help & Advice
- Machine Safety Shop
Filter products
Leak Testing Complete Set BPS 03 by Aquametrics for Leak Tests with Water
BPS 03 Complete Set for Leak Testing with Water Leak detection device by Aquametrics as a level measurement device for leak testing. Fast and easy operation of the measurement system for leak tests with water in pipelines and shafts, conducted as a water level probe.Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you. Water-Level Probe Execution of leak testing for pipelines and shafts according to the following standards: DIN 1986-30:2012-02 DIN EN 1610 DWA A-139 The high accuracy of the probe has been confirmed by LGA in Würzburg. The AquaDP software (only in German) functions as a standalone version and includes the module "Wasser" as a part of the software. Advantages High measurement accuracy even at low immersion depth Level probe as a capacitive transmitter High-quality ceramic measurement cell with pressure and temperature compensation Probe can be directly used in wastewater Probe extendable via chain (instead of pipe guidance) Probe head can be used without tripod Probe usable up to 10 m immersion depth (overload up to 300 mbar) Up to 4 probes can be used simultaneously (optional) Explosion-proof probe available as an option Coarse filter included in the kit Robust probe height adjustment for construction site use Easy connection to PC or tablet via USB Powered via USB with minimal power consumption Our tests are performed according to standards such as DIN EN 1610, DWA-A 139, DIN 1986-30, DWA-M 149-6, DIN 1999-100, DIN 4040-100, DIN EN 805, and DVGW-W400. Scope of Delivery Aluminum tripod with triple height adjustment With plastic screw connection M50 for probe adjustment Test probe in ABS plastic transport case PVC pipe DN40 for holding the test probe 2 x 1.2 m with connection coupling DN40 Pipe end caps DN40 for probe extension with chain, etc. Coarse material filter attachable as probe protection for wastewater with fiber materials, etc. Robust splash-proof converter with probe connection socket and USB output Test software AquaDP (in German) as a standalone version with the software modules "Wasser" as part of the software. For installation on Windows operating systems from WIN 7. For tablet, laptop, and office PC applications. (Windows 32-/64-bit) Free online updates, always the latest standards and software versions available. Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Flexible Pipe Sealing Pads PU-F 70 - 1600 mm
The lightweight and flexible sealing pad design of type PU-F without metal core applicable at 2.5 bar operating pressure up to 1,000 mm is suitable for fast and reliable sealing. Can also be used to shut off sewers, pipelines and drainage inlets. These test pipe stoppers are mainly used for repairs, maintenance, accidents and leak tests with water or air according to DIN EN 1610 of newly laid or renovated pipelines. Ideal aid for water management organizations, rescuers and fire departments, but also in the construction industry and industry. The flexible test bladder PU-F is made of high-quality rubber material with fabric insert and is therefore weather- and temperature-resistant in a temperature range from -30 oC to 80 oC as well as use- and waste water-resistant. The product is available in 11 standard versions with diameters ranging from 70 mm to 1600 mm. These test bubbles are tested at 1.3 times the operating pressure and can be used at a back pressure of 10 or 5 m WS. An operating manual is enclosed with each sealing pad. Attention: Please note that we also offer some models of bladders with two passages, but others only with one passage. However, for the version that is only available with one passage due to the manufacturer, adapters with two connections for air or water testing would be available from us on request (please see data sheet on the german page under downloads). Our pipe cushions & shut-off plugs are made of expandable material and can be filled with liquid or air. (Classification in category A - pipe sealing pillows and renovation packers of the resistance list; see picture)
House Connection Testing System - Complete Set by Aquametrics with Measuring Device RPS03
Aquametrics House Connection Testing System – Complete Set with Measuring Device (RPS03) Complete solution for leak testing of house connections using air. Optionally also suitable for water testing. DIN EN 1610 DIN EN 1986-30 DWA A-139 Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Advantages Practically developed in-house – “By inspectors – for inspectors” Easy transport in a durable plastic case Test bladder with aluminum core – lightweight and user-friendly Short design length – ideal for narrow manholes and inspection openings Test bladder can be used independently without push hose Precise positioning via push hose with locking compression fitting Flexible push and sealing bladders for use in pipe bends Standard-Compliant Testing Our leak tests are performed in accordance with the following standards: DIN EN 1610 DWA-A 139 DIN 1986-30 DWA-M 149-6 (formerly ATV-M 143-6) DIN 1999-100 DIN 4040-100 DIN EN 805 DVGW-W400 Versatile Applications Our measuring systems are also commonly referred to as: Test case, pressure test case, pressure measurement case, sealing case Water level probe, manhole probe Water level test, septic tank test, small treatment plant test, container test, collection tank test, water pressure test House connection test, house connection tester, house connection testing unit Vacuum test, negative pressure test, vacuum ejector Leak testing of private wastewater pipes and sewer systems Scope of Delivery Aquametrics house connection testing system with sealing bladder Handheld measuring device (RPS03 system)Push rod 12 m (blue) Durable plastic case AquaDP software (module "Luft") on USB flash drive - in German Test documentation with data logging, time curve, and export as PDF Option to insert images into the test report Optional: Water testing module available Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Test Pipe Sealing Pad PU for Pipe Diameters 70 - 1200 mm
The rigid standard test pipe sealing pad PU with metal core ensures fast and reliable sealing. This pipe sealing pad can also be used to shut off sewers, pipelines and drainage inlets. Test blisters are mainly used for maintenance measures, repairs, accidents and leak tests with water or air according to DIN EN 1610 of newly laid or renovated pipelines. Important aid for water management organizations, rescuers and fire departments, but also in the construction and industrial sectors. The pipe sealing pad is weather- and temperature-resistant in a temperature range from -30 oC to 80 oC and resistant to wear and waste water. The pipe sealing cushion PU is available in 5 standard versions with diameters from 70 mm to 1200 mm. These sealing pad products are tested at 1.3 times operating pressure and can be used at a back pressure of 10 or 5 m WS. An instruction manual is attached to each test pad. Attention: Please note that we also offer some models of bladders with two passages, but others only with one passage. However, for the version that is only available with one passage due to the manufacturer, adapters with two connections for air or water testing would be available from us on request (please see data sheet on the german page under downloads). Our pipe cushions & shut-off plugs are made of expandable material and can be filled with liquid or air. (Classification in category A - pipe sealing pillows and renovation packers of the resistance list; see picture)
Complete set by Aquametrics for testing pipe plugs and pipe sealing cushions, measurement system for APS02
Aquametrics Testing System APS02 for Airbags and Pipe Sealing Cushions Airbag testing according to GUVG 9102, BDI 802, ArbSchG, BetrSichV and others. Save time and costs by quickly and easily performing the annual inspection of airbags and sealing cushions yourself! (This inspection may only be performed by qualified personnel.)Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Scope of Delivery Handheld measuring device with 0.1 mbar resolution (RPS03) USB 2.0 data cable, 1 m (charging cable) 5 m test hose with compressed air quick connector NW 7.2 Y-piece (brass) with 2 coupling sockets and 1 quick connector NW 7.2 High-quality ABS plastic case Test and documentation software Aqua BP (in German) on USB memory stick Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Flexible Test Pipe Sealing Cushions Oil-Resistant PUOEL
The lightweight and flexible test cushion design of type PUOEL without metal core is suitable for use at 2.5 bar operating pressure up to 1,000 mm for quick and reliable sealing. It can also be used for shutting off channels, pipelines, and drainage inlets. These test pipe sealing cushions are primarily used for repairs, maintenance, accidents, and leak tests with water or air in accordance with DIN EN 1610 for newly installed or renovated pipelines. An ideal tool for water management organizations, rescue services, and fire brigades, as well as in construction and industry. The flexible PUOEL test cushion is made of high-quality rubber material with fabric reinforcement, making it weather- and temperature-resistant within a range of -30 °C to 80 °C, as well as resistant to fresh water and wastewater. The product is available in 7 standard versions with diameters ranging from 70 mm to 1200 mm. These test cushions are tested at 1.3 times the operating pressure and can be used at a back pressure of 10 or 5 m water column. Each sealing cushion is supplied with an operating manual. Our pipe sealing cushions & shut-off cushions are made of stretchable material and can be filled with liquid or air. (Classified in category B – pipe sealing cushions and rehabilitation packers of the resistance list; see image)
Sanitester Pressure Test Unit, Pipe Testing System, DIN EN 1610
Sanitester pressure test case according to DIN EN 1610 (German basic standard for laying and testing wastewater pipes and sewers). Premium product made in Slovenia.This 3-in-1 test case contains all the necessary connections for the following types of leak testing: Water Testing, Manhole Inspection, High Pressure Tests. Please note: The individual sensors are not included in the scope of delivery, but can be ordered here in the shop. Please click on the corresponding test procedure to display the price and order number: Sensor water test Sensor manhole test Sensor high pressure test An annual license fee may apply for the current software (see video in the image gallery). We would be happy to provide you with further information in a personal consultation. Do you need something else? We carry a wide selection of test pipe sealing cushions as well as small and large pipe plugs and shut-off discs with bypass especially for house connection testing. You can find the entire offer in the category >> Leak & House connection Testing Equipment.
House Connection Pipe Testing System DS 8/15
House connection pipe testing system for leak tests of house connections of 80-150 mm nominal diameter with air. Includes a test bladder for air. (Test bladder for air and water optional at extra charge.) The set is suitable for testing straight pipe sections as well as bends and knee pipes up to 90°. It optionally contains a digital manometer as well as all fittings and accessories required for leak tests according to DIN EN 1610. The ISO 9001 certified set contains the following individual parts: 1 pcs. Test pipe sealing pad for air HPU 8/15 1 pcs. Pipe sealing pad HU 8/15 1 pcs. Filling armature with pressure gauge 04 bar 1 pcs. Test armature for the leak test with air 1 pcs. Digital manometer with hose, 1 m pushing bar 4 pcs. 2 m, 1 pc. 1 m, 2 pcs. 0,5 m 1 pcs. Holding rope with snap hook, 10 m 1 pcs. Reduction MINI/V 7.2/R 1 pcs. Reduction MINI/R 7.2/V 1 Transport case You prefer to use WATER as a test medium? No problem! On request, the set is also available with a pipe stopper for air and water tests HPU 8/15 W. You can choose to replace the standard air plug (= HPU 8/15) with the alternative water plug (= HPU 8/15 W) or order an extended kit with both pipe stoppers. Please contact us so that we can put together a customised package for you.
Sensor for Water Testing, Drain Pipe Tests
Sensor 0-1 bar for water testing - accessory for the Sanitester pressure test case.This system complies with DIN EN 1610 (German basic standard for laying and testing wastewater pipes and sewers). Premium product made in Slovenia.Please note: This item is the sensor for water testing only. Additional sensors are not included in the scope of delivery, but can be ordered here in the shop. Please click on the corresponding test procedure to display the price and item number: Sensor high pressure test Sensor manhole test For house connection testing, we carry a wide selection of test pipe sealing cushions as well as small and large pipe end caps and shut-off disks with passage. You benefit from our low shipping costs and fast delivery times.You can find the entire offer in the category >> Testing technology.
Sensor for Manhole Testing, Vacuum Sewer Shaft Tests
Sensor for manhole testing - accessory for the Sanitester pressure test case.This system complies with DIN EN 1610 / 1508 (German basic standard for laying and testing wastewater pipes and sewers). Premium product made in Slovenia.Please note: This sensor is for sewer shaft testing only. Additional sensors are not included in the scope of delivery, but can be ordered here in the shop. Please click on the corresponding test procedure to display the price and item number:Sensor water testSensor high pressure test For house connection testing, we carry a wide selection of test pipe sealing cushions as well as small and large pipe end caps and shut-off disks with passage. You benefit from our low shipping costs and fast delivery times.You can find the entire offer in the category >>Leak & House Connection Testing Equipment.
Sensor for High Pressure Testing, Drain Pipe Tests
Sensor for high pressure testing - accessory for the Sanitester pressure test case.This system complies with DIN EN 1610 (German basic standard for laying and testing wastewater pipes and sewers). Premium product made in Slovenia.Please note: This sensor is made for high pressure testing. Additional sensors are not included in the scope of delivery, but can be ordered here in the shop. Please click on the corresponding test procedure to display the price and item number:Sensor water testSensor manhole test For house connection testing, we carry a wide selection of test pipe sealing cushions as well as small and large pipe end caps and shut-off disks with passage. You benefit from our low shipping costs and fast delivery times.You can find the entire offer in the category >> Leak & House Connection Equipment.
Steam Pipe Test Plug For Steam Dissipation, 100 - 600 mm
These steam pipe test plugs are very strong shut-off plugs that are used to shut off and drain pipes containing steam and in which steam pressure prevails. They are made by vulcanizing SBR+NR rubber and high-strength fabric. The temperature range of the test plug is between -30°C and +70°C. The large bypass enables quick steam escape from the pipe. It can therefore be used, for example, for testing district heating pipes. The steam pipe test plug also contains a large metal core so that the steam can be drained away quickly. It is available in various designs for pipe diameters from 100 - 600 mm, the working pressure is 2.8 bar.This test plug can be made with NBR rubber, which is resistant to gas, petroleum and their derivatives, for an additional charge.
High Pressure Sewer Test Plug With Bypass, Up To 3 Bar Counter Pressure, 70 - 1000 mm
High-pressure sewer test plug with bypass, for up to 3 bar counter pressure, at a Top price-performance ratio!. High-pressure sewer pipe test plugs are used to temporarily shut off pipelines with high counter pressure. The dimensionally stable test plugs are made by vulcanizing SBR+NR rubber and high-strength fabrics. The strong profile grooves give the test plug stability and ensure a secure hold in pipes and sewers. Our high-pressure test bladder with bypass (size 1/2" - 2", depending on the model, see technical data) is the ideal product type for shutting off pipes with a backflow height of up to 30 meters. These pipe test plugs can withstand up to 3 bar counter pressure. The high-pressure test plugs are available in various diameter ranges for pipes from DN 70 to DN 1000. They are temperature-resistant at temperatures between -30°C and +70°C. The maximum working pressure is 6.0 bar (see technical data). For an additional charge, the sewer test plug can be made from NBR rubber, which is resistant to gas, petroleum and derivatives.
House Connection Pipe Testing System DS 10 - 20
House connection pipe testing system for leak tests of house connections of 80–150 mm nominal diameter with air. (Test bladder for air and water optional at extra charge). The set is suitable for testing straight pipe sections as well as bends and knee pipes up to 90°. It optionally contains a digital manometer as well as all fittings and accessories required for leak tests according to DIN EN 1610. . The ISO 9001 certified set contains the following individual parts: 1 pcs.Test pipe sealing pad HPU 10/20 1 pcs. Pipe sealing pad HU 10/20 1 pcs. Filling armature with pressure gauge 04 bar 1 pcs. Compressed air adapter for air testing 1 pcs. Stopcock G1" with GEKA couplings 1 pcs. float 1 pcs. safety fitting 300 mbar for air testing pushing bar 4 pcs. 2 m, 1 pc. 1 m, 2 pcs. 0,5 m 1 pcs. Adapter for digital manometer 1 pcs. Venting and test hose with GEKA couplings, 5 m 1 pcs. Holding rope with snap hook, 10 m 1 pcs. Reduction MINI/V 7.2/R 1 pcs. Reduction MINI/R 7.2/V 1 Transport case
Egg Profile Sealing Pillow PUV PUVP
The suitable sealing pad for sealing and testing larger diameters of egg-shaped channels. The egg-shaped pipe sealing pillow type PUV, PUV-F and PUVP is pillow-shaped for sealing larger diameters, since the egg-shaped design cannot be introduced into the sewer system through the manhole due to its size. 8 different egg sizes from 300 mm to 1350 mm are available. Our pipe stoppers & shut-off plugs are made of expandable material and can be filled with liquid or air. (Classification in category A - pipe sealing pillows and renovation packers of the resistance list; see picture)
Manhole Test Sealing Pad US 600 - 1500 mm
Sealing cushion for manhole testing applicable with air pressure and vacuum. Easy handling due to its light and short form. The sealing pillow standard version is in size L and light. Our pipe cushions & shut-off plugs are made of expandable material and can be filled with liquid or air. (Classification in category A - pipe sealing pillows and renovation packers of the resistance list; see picture)
PULK Conical Pipe Sealing Cushion for Testing, DN 150–2200, Pipe Plug with Bypass
PULK series with bypass offers a wide range of applications. Cone-shaped pipe stoppers are typically used for pipeline repair, rehabilitation, maintenance, and leak testing. Thanks to their design, they can be used in egg-shaped, rectangular, and other non-circular profiles. They are manufactured from high-quality, chemically resistant materials. Minor external damage can easily be repaired by the user – our team will be happy to advise you on the appropriate repair kit. 7 different sizes in diameters from 150 mm to 2200 mm are available. Our conical pipe stoppers and shut-off plugs are made of non-stretchable material and can be filled with liquid or air. (Classification in category C – pipe stoppers and renovation packers of the resistance list; see picture)
Protective Rubber for Pipe Stoppers Type U and PU-F
Properties and further information on the various sealing pads and protective rubbers can be found on this page under "Technical Details".
Leak Testing System (BPS03 GI by Aquametrics) Separator Inspection as Part of General Inspection
Aquametrics Leak Testing System (BPS03 GI)/ Separator Inspection as Part of General Inspection Fields of Application Water level testing (e.g., fill level test or water level measurement) as well as leak testing of pipelines, manholes, and separator systems such as oil or gasoline separators. Leak tests on grease separators can also be performed quickly and easily. Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Applicable Standards DIN 1986-30:2012-02 DIN EN 1610 DWA A-139 The high measurement accuracy of our level probe has been tested and certified by TÜV Rheinland / LGA in Würzburg. A corresponding test certificate is included. Software The AquaDP software is offered as a single-user solution (currently only in German). It includes modules for separator inspection and water level measurement (Wasser + GI). Suitable for Separator Systems According to: DIN 1999-100 DIN 4040 Your Advantages Highly accurate measurement results – even at low immersion depths Level probe with capacitive measurement principle Durable ceramic measuring cell with pressure and temperature compensation Direct use in wastewater possible Probe extension via chain (instead of pipe guide) Probe head can also be used separately without a stand Usable up to 10 m immersion depth without damage (overload protection up to 300 mbar) Supports connection of up to 4 probes simultaneously (optional) Optional EX-protected version available Coarse particle filter included as attachment in the case set Very robust height adjustment with plastic screw fitting – ideal for use on construction sites Simple USB connection to PC or tablet USB power supply directly from the device Low power consumption – long operating time Testing According to the Following Standards: DIN EN 1610 DWA-A 139 DIN 1986-30 DWA-M 149-6 (formerly ATV-M 143-6) DIN 1999-100 DIN 4040-100 DIN EN 805 DVGW-W400 Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Leak Testing Device BPS KKA by Aquametrics for Small Wastewater Treatment Plants and Collection Pits
Aquametrics Leak Testing Device (BPS KKA) for Small Wastewater Treatment Plants and Collection PitsNote: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Water level testing (water fill test, level measurement) for leak testing of small wastewater treatment systems and collection pits in accordance with: DIN 1986-30:2012-02 DIN EN 12566 DIN 4261-1 and others The probe’s measurement accuracy has been confirmed by the LGA in Würzburg. The included software AquaDP (in German) is available as a single-user version and includes the modules "KKA" and "Wasser" as a subcomponent. Advantages High measurement accuracy even at shallow immersion depths Level probe as capacitive transmitter High-quality ceramic measuring cell with pressure and temperature compensation Probe can be used directly in wastewater Probe extension via chain (instead of pipe guidance) Probe head can be used separately, without tripod Suitable for immersion depths up to 10 m without damage (overload up to 300 mbar) Use of up to 4 probes simultaneously (optional) Optional probe available with EX protection Coarse filter included as plug-on attachment in carrying case Durable height adjustment via plastic screw – ideal for construction site use Simple USB connection to PC or tablet Power supplied via USB from tablet or notebook Low power consumption for extended operating time Our tests are carried out in accordance with the following standards: DIN EN 1610 DWA-A 139 DIN 1986-30 DWA-M 149-6 (formerly ATV-M 143-6) DIN 1999-100 DIN 4040-100 DIN EN 805 DVGW-W400 Scope of Delivery Aluminum tripod with triple height adjustment M50 plastic screw fitting for probe adjustment Test probe in durable ABS plastic case 2 × 1 m PVC pipe DN40 with coupling for probe housing AquaDP software in German as single-user version with modules for small wastewater plants and collection pits (KKA + Wasser) Recording of all object-related and test-relevant data Usable test report available as printout or PDF Rugged converter in aluminum housing with connectors for probe and mini USB2 Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Automatic Water Pressure Testing Unit by Aquametrics for Pipe Pressure Tests According to EN 1610
Automatic water pressure testing unit for tests according to EN 1610 (pipe pressure) with water, in combination with the Aquametrics software "Aqua DP 2.3". Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you. During the pressure test according to EN 1610 – water pressure – the pressure corresponding to the maximum backwater level at the lowest node must be maintained for 30 minutes. The amount of refilled water during this period is essential for evaluation. The WDPS system, in combination with the Aqua DP software (in German), performs this task fully automatically: It detects pressure loss during the test via a pressure transmitter installed at the lowest point and automatically refills water if the defined test pressure is undershot. The refilled water volume is continuously measured by a flow sensor and transmitted directly to Aqua DP. The test pressure is maintained constantly throughout the test period. The hysteresis, i.e., the pressure range to be applied (in mbar), can be individually adjusted in the Aqua DP software settings. This is particularly helpful for adapting to different test containers – because: mbar is not the same as liters. For the standard test container from Aquametrics (100 mm), a hysteresis of 6–8 mbar has proven to be optimal. With larger diameters, the hysteresis should be set lower – or as needed. For example, if a pipeline is only allowed to lose 0.8 liters, a suitable test container must be used to measure the water volume accurately.Scope of Delivery Software AquaDP 2.3.x (in German) Measuring system WDPS01 Test probe with 5-meter cable Standpipe / Test cylinder DN200 USB connection cable Clear filling hose, 5 m with GK coupling Plug-in power supply 230V Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
House Connection Testing System with Air (without RPS03 Measuring Device)
House Connection Testing System with Air (without RPS03 measuring device) Aquametrics testing system for leak detection in house connections. Optionally also suitable for water testing. DIN EN 1610 DIN EN 1986-30 DWA A-139 Note: The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you.Advantages Practical in-house development – “By inspectors – for inspectors” Test bladder with aluminum core – lightweight and easy to handle Very short design – ideal for tight manholes and inspection openings Test bladder can be used independently without push hose Precise positioning via push hose with locking (compression fitting) Excellent flexibility of push and sealing bladders in bends Our tests are conducted in accordance with the following standards: DIN EN 1610 DWA-A 139 DIN 1986-30 DWA-M 149-6 (formerly ATV-M 143-6) DIN 1999-100 DIN 4040-100 DIN EN 805 DVGW-W400 Scope of Delivery Aquametrics house connection testing system with sealing bladder Push bladder as conical pipe sealing cushion 12.5 m push hose Y-distributor for compressed air NW7.2 Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Measuring Device (RPS03 Solo) for Leak Testing of Pipelines and Manholes Using Air
Leak Testing System with Air For positive pressure and negative pressure testing of pipelines up to 200 mbar. DIN EN 1610 DIN 1986-30 DWA A-139 Suitable as an extension or supplement to existing test bladders. The required measurement accuracy according to DIN EN 1610 has been verified by expert report. Note: No data logger function! Recording is done directly via the AquaDP software. The software for Aquametrics products is currently only available in German. If this is a concern, our technical customer support team is happy to assist you. Advantages For measuring overpressure, underpressure and differential pressure Six differential pressure ranges from precision manometer Barometric pressure sensor and temperature compensation for highly accurate readings Large TFT color display (W × H: 45 × 60?mm) Measurement display in 9 different units: mbar, Pa, hPa, kPa, mmWS, mmHg, inWC, psi, bar Fully automatic device check, manual and automatic zero-point adjustment on program start Our tests are conducted according to the standards: DIN EN 1610, DWA-A 139, DIN 1986-30, DWA-M 149-6.Scope of Delivery Measuring device with power supply and data cable Calibration certificate Protective device cover with magnet Software (in German) on USB memory stick Bluetooth dongle for data transfer Aluminum transport case Maintenance and Service Depending on the operating conditions, checking the measurement system is absolutely necessary. The recalibration interval depends on the specific application conditions (e.g., separator inspection). Recommended recalibration interval: 1 year. Deposits on the ceramic membrane can lead to signal changes. In such cases, the ceramic membrane can be carefully cleaned of deposits using a commercially available descaler and a brush or soft bristle brush. Afterwards, rinse with cold water.
Cable Extension for Aquametrics Measuring Systems - Probe Cable Extension 10m
Durable cable extension for Aquametrics BPS03 measuring system. Equipped with connector, socket, and protective caps for secure outdoor use. Length: 10 meters Connector with protective cap Splash-proof design for outdoor applications